Draw a pencil line along the.
Ada toilet grab bar height.
The icc a117 1 standard for accessible and usable buildings and facilities which is referenced by the international building code requires an 18 min.
For 3 and 4 year olds bars should be 18 20 inches from the floor for 5 to 8 year olds bars should be 20 25 inches and for 9 to 12 year olds grab bars should be 25 27 inches.
Water closet seat heights shall be between 17 inches 430 mm and 19 inches 485 mm.
The guidelines for children s toilets are found in ada tas section 604 9.
A 42 inches 1065 mm minimum length grab bar is required on the side wall spaced a maximum of 12 inches 305 mm from the back wall and extending a minimum of 54 inches 1370 mm from the back wall at a height of 33 36 inches 840 915 mm.
Two grab bars shall be installed on the back wall one located in accordance with 609 4 and the other located 8 inches 205 mm minimum and 10 inches 255 mm maximum above the rim of the bathtub.
The height of the toilet seat shall be 17 to 19 inches 430 485 mm above the finished floor.
Toilet paper dispensers shall be below the grab bar and at least 19 inches 485 mm above the floor and no farther than 36 inches 915 mm from the rear wall measured to the far side of the dispensers.
A 42 inches 1065 mm minimum length grab bar is required on the side wall spaced a maximum of 12 inches 305 mm from the back wall and extending a minimum of 54 inches 1370 mm from the back wall at a height of 33 36 inches 840 915 mm.
Vertical grab bar at water closets.
Each grab bar shall be 24 inches 610 mm long minimum and shall be installed 24 inches 610 mm maximum from the head end wall and 12 inches 305 mm maximum from the control end wall.
The toilet paper dispenser shall be mounted below the grab bar at a minimum height of 19 inches 485 mm.
The toilet paper dispenser shall be mounted below the grab bar at a minimum height of 19 inches 485 mm.
1 the location of the toilet measured from the side wall to the centerline should be between 12 18 2 the height of water closets should be between 11 17 to the top of the seat.
In addition the grab bar heights for children are found in 609 4.
The ada standards do not require this grab bar but allow a second grab bar to be within the 12 clearance above the horizontal grab bar 609 3 if there is a separation of 1 min.
Ada specifies that grab bars must be positioned between 33 and 36 inches above the floor so centering the bar at 34 5 inches ensures you will fall within this range.
Grab bars enlarging toilet stalls insulating pipes or installing accessible faucet controls.