Interior accessible doors should require no more than 5 lbs.
Ada interior door opening force.
The minimum force needed to ensure proper closure and positive latch usually exceeds the accessible limit of 5 pounds of force lbf required at other doors.
Open the door gradually.
5 pounds 22 2 n.
The force for pushing or pulling open a door or gate other than fire doors shall be as follows.
The maximum opening force for interior hinged doors is 5 pounds.
B interior hinged doors.
Do not jerk it open.
Fire doors shall have a minimum opening force allowable by the appropriate administrative authority.
The maximum force for pushing or pulling open a door shall be as follows.
This does not apply to the initial force needed to overcome the weight of a motionless door.
The ada standards do not specify the opening force for exterior doors though some state and local building codes may have requirements.
Of force to open.
Typical maximum opening force for exterior.
5 pounds 22 2 n maximum.
The opening force requirements are the same for both the 2009 edition of icc a117 1 accessible and usable buildings and facilities section 404 2 8 and the 2010 americans with disabilities act standards section 404 2 9.
The requirements for door opening force are found in the americans with disabilities act accessibility guidelines adaag icc ansi a117 1 standard on accessible and usable buildings and facilities and the massachusetts architectural access board requirements 521 cmr.
Interior hinged doors and gates.
Typical maximum opening force for exterior.
Door opening force fire doors shall have a minimum opening force allowable by the appropriate administrative authority.
Sliding or folding doors.
This applies to interior hinged doors and gates as well as sliding and folding doors.
Door opening force is the measurement of how many pounds of force are required to open a door.
Opening force for exterior doors is not specified in the ada standards but exterior doors that need to be accessible should have the minimum force possible.
5 pounds 22 2 n maximum.
In this video mark trieglaff illustrates how to measure door opening force to meet compliance with 2010 adaag codes.
A exterior hinged doors.
404 2 9 door and gate opening force.
1 fire doors shall have the minimum opening force allowable by the appropriate administrative authority.
The opening force of exterior swing doors is impacted by wind loading and other exterior conditions gasketing hvac systems energy efficiency and the weight of doors.