If the latch side clearance is at least 42.
Ada door pull side clearance.
The ada home page provides access to americans with disabilities act ada regulations for businesses and state and local governments technical assistance materials ada standards for accessible design links to federal agencies with ada responsibilities and information updates on new ada requirements streaming video information about department of justice ada settlement agreements.
Of 54 x48 if the door includes both a closer and a latch.
Maneuvering clearances shall extend the full width of the doorway and the required latch side or hinge side clearance.
48 inches 1220 mm 0 inches 0 mm 1.
Entry doors to hospital patient rooms shall not be required to provide the clearance beyond the latch side of the door.
Door or gate side.
For a hinge side approach on the push side of a swinging door there must be a clear space in front of the door that measures 54 x42.
Entry doors to hospital patient rooms shall not be required to provide the clearance beyond the latch side of the door.
The depth can be 54 min.
Pull side 44 push side min per cbc 60 24 per cbc 24 48 min 54 min min pull side push side.
Minimum maneuvering clearances at doors and gates shall comply with 404 2 4.
The maneuvering clearance at the door with a 36 door is then 48 x 60.
60 inches 1525 mm 36 inches 915 mm from hinge side.
On the pull side of hinge approaches 36 min.
The clear space must measure a min.
On the parallel side beyond the latch is 24 inches should the door need to swing open.
Door clearances sources 26 ada sources 309 operable parts 404 2 manual doors doorways and manual gates 404 2 2 double leaf doors and gates.
Space at least 60 deep in front of a door will accommodate a forward approach except in case of hinge approaches on the pull side.
48 perpendicular to the doorway without closer 54 with closer but still have 24 parallel to doorway beyond latch.
Parallel to doorway beyond latch side unless noted from front.
Latch side clearance is required if the depth is 60 min.
This is based on a new door installation or a door that is on an accessible route.
404 2 4 1 swinging doors and gates swinging doors and gates shall have maneuvering clearances complying with table 404 2 4 1.
Latch approach pull side of door.
Front approaches to pull side of swinging doors shall have maneuvering space that extends from the hinge side of the door to 18 inches 455 mm minimum 24 inches 610 mm preferred beyond the latch side of the door and 60 inches 1525 mm minimum perpendicular to the doorway.
Figure 25 a front approaches swinging doors.