Pulls should provide sufficient knuckle clearance 1 minimum to facilitate gripping.
Ada bathroom stall door requirements.
The ada compliant restroom.
Certain ada compliance issues seem to crop up more frequently than others but it s important to note that the following is not an exhaustive list.
Hinge side approaches a side approach toward the hinge side of the door to the pull side of swinging doors shall have maneuvering space that extends 36 inches 915 mm minimum beyond the latch side of the door if 60 inches 1525 mm minimum is provided perpendicular to the doorway or maneuvering space that extends 42 inches 1065 mm minimum beyond the latch side of the door if 54 inches 1370 mm minimum is provided perpendicular to the doorway.
An example of a single ada bathroom layout.
To see all of the ada compliance requirements see the 2010 ada standards for accessible design at www ada gov.
However the enclosure walls must meet certain dimensional requirements.
All standard stalls must be at least 60 inches wide.
In standard stalls the front partition and at least one side partition shall provide a toe clearance of at least 9 in 230 mm above the floor.
Two alternate stalls are permitted for alterations only.
In either alternate stall if a wall mounted water closet is used the depth of the stall is required to be a minimum of 66 inches 1675 mm.
The other alternate stall is required to be a minimum of 48 inches 1220 mm wide.
Toilet stall doors including door hardware shall comply with 4 13.
If the depth of the stall is greater than 60 in 1525 mm then the toe clearance is not required.
Toilet stall accessible toilet stalls or compartments must have a minimum width of 60 inches and sufficient space to accommodate a wheelchair to the sides of the toilet or in front of it.
Multiple toilet stall layouts.
Stall width 60 minimum inside clear stall depth 56 minimum inside clear with wall mounted toilets 59 minimum inside clear with floor mounted toilets standard walk in 36 wide compartment ambulatory accessible compartment with an outswinging door for washrooms with six or more toilets.
In a public bathroom that has stalls at least one must be a standard ada stall.
For commercial bathrooms with multiple toilet stalls and handicap the rules change a little.
The toilet must be centered on the back wall.
In a corner handicap stalls require a minimum of 60 x 60 compartment and is required with a minimum door size of 32 and the maximum size and more common is the 36 door.
5 common ada restroom compliance mistakes.
One alternate stall is required to be 36 inches 915 mm wide.